Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 47
Filter
1.
Acta ortop. bras ; 31(2): e263742, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1439138

ABSTRACT

ABSTRACT Objective: To evaluate the clinical and radiographic results of the surgical treatment of fractures of the middle third of the clavicle, using the technique of minimally invasive plate osteosynthesis (MIPO) with locking. Methods: Prospective case series, evaluating displaced fractures of the middle third of the clavicle submitted to MIPO with locking, with procedures performed by a single surgeon. Patients were evaluated at 12 months using the University of Los Angeles (UCLA) scale and anteroposterior radiographs of the clavicles with 45° cranial and caudal inclination, as well as reporting complications. Results: In total, 15 patients were evaluated. The median of surgical time was 50 minutes (IQR 35). The UCLA scale had a median of 35 (IQR 2) at 12 months. All patients presented fracture healing. Minor complications occurred in three cases (20%), with two (13.3%) evolving with plate prominence and one (6.7%) with local paresthesia, while major complications occurred in only one case (6.7%), with suture dehiscence requiring surgical re-approach. Conclusion: MIPO with locking is a viable option for the treatment of displaced fractures of the middle third of the clavicle, with excellent results according to the UCLA scale, fracture healing in all cases, and a low rate of complications. Level of Evidence IV, Case Series.


RESUMO Objetivo: Avaliar os resultados clínicos e radiográficos do tratamento cirúrgico de fraturas do terço médio da clavícula pela técnica de osteossíntese minimamente invasiva com placa (OMIP) bloqueada. Métodos: Série de casos prospectiva que avaliou fraturas desviadas do terço médio da clavícula submetidas à OMIP bloqueada, com procedimentos realizados por um único cirurgião. Os pacientes foram avaliados aos 12 meses por meio da escala da Universidade da Califórnia em Los Angeles (UCLA) e por radiografias das clavículas em anteroposterior (AP) com inclinação cranial e caudal de 45°, além de relatos de complicações. Resultados: Foram avaliados 15 pacientes. A mediana do tempo cirúrgico foi de 50 minutos (IIQ 35). A escala da UCLA aos 12 meses teve mediana de 35 (IIQ 2). Todos os pacientes apresentaram consolidação da fratura. Complicações menores ocorreram em três casos (20%): dois (13,3%) com proeminência da placa e um (6,7%) com parestesia local. Maiores complicações ocorreram em apenas um caso (6,7%), com deiscência de sutura, necessitando de reabordagem cirúrgica. Conclusão: A OMIP bloqueada se mostrou uma opção viável ao tratamento das fraturas desviadas do terço médio da clavícula, com resultados excelentes de acordo com a escala UCLA, consolidação em todos os casos e baixo índice de complicações. Nível de Evidência IV, Série de Casos.

2.
Acta ortop. bras ; 31(spe2): e263313, 2023. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1439144

ABSTRACT

ABSTRACT Objective This study investigated the factors associated with satisfactory early postoperative wound conditions. Method A prospective study was conducted with patients (n=179) submitted to osteosynthesis in general, in a hospital orthopedics service. In the preoperative period, patients underwent laboratory exams and the surgical indications were based on the type of fracture and the patient's clinical conditions. In the postoperative period, patients were evaluated based on the presence of complications and considering their surgical wounds. Chi-square, Fisher, Mann-Whitney, and Kruskal-Wallis tests were used in the analysis. To identify the factors associated with wound condition, univariate and multiple logistic regression analysis was used. Results In the univariate analysis, each transferring unit reduction increased the chance of satisfactory outcome by 1.1% (p=0.0306; OR= 0.989 (1.011); 95%CI= 0.978;0.999; 1.001;1.023). The presence of SAH increased 2.7 fold the chance of satisfactory outcome (p=0.0424; OR= 2,667; 95%CI= 1,034;6,877). Hip fracture increased 2.6 fold the chance of satisfactory outcome (p=0.0272; OR=2.593; IC95%=1.113; 6.039). And the absence of a compound fracture increased 5.5 fold the chance of satisfactory wound outcome (p=0.0004; OR=5,493; 95%CI=2,132;14,149). In the multiple analysis, patients with non compound fractures were 9.7 times more likely to experience a satisfactory outcome when compared to patients with compound fractures (p=0.0014; OR=9,687; 95%CI= 2,399; 39,125). Conclusion There was an inverse relationship between plasma proteins levels and satisfactory surgical wounds outcome. Only exposure remained associated with wound conditions. Level Of Evidence: II, Prospective Study.


RESUMO Objetivo Este estudo investigou os fatores associados à condição satisfatória de ferida pós-operatória precoce. Método Foi desenvolvido um estudo prospectivo com pacientes (n=179) submetidos a osteossínteses em geral, em um serviço de ortopedia hospitalar. No período pré-operatório os pacientes foram submetidos a exames laboratoriais e as indicações cirúrgicas foram baseadas no tipo de fratura e condições clínicas. No período pós-operatório, os pacientes foram avaliados conforme a presença de complicações e feridas operatórias. Foram utilizados na análise os testes Qui-quadrado, Fisher, Mann-Whitney, Kruskal-Wallis. Para identificar os fatores associados à condição da ferida, foi utilizada a análise de regressão logística univariada e múltipla. Resultados Na análise univariada, cada unidade a menos de transferrina, aumentou a chance de condição satisfatória em 1.1% (p= 0.0306; OR= 0.989 (1.011); IC95%= 0.978;0.999; 1.001;1.023). A presença de HAS aumentou a chance de condição satisfatória em 2.7 vezes (p=0.0424; OR= 2.667; IC95%= 1.034;6.877). Fratura de quadril aumentou a chance de condição satisfatória em 2.6 vezes (p=0.0272; OR=2.593; IC95%=1.113;6.039). E não apresentar fratura exposta, aumentou a chance de condição satisfatória da ferida em 5.5 vezes (p=0.0004; OR=5.493; IC95%=2.132;14.149). Na análise múltipla, fraturas sem exposição, apresentaram chance 9.7 vezes maior de apresentar condição satisfatória do que insatisfatória; quando comparadas às que apresentaram exposição (p=0.0014; OR=9.687; IC95%= 2,399; 39.125). Conclusão Houve uma relação inversa entre proteínas plasmáticas e presença de feridas operatórias satisfatórias. Apenas a exposição se manteve associada à condição da ferida. Nível de Evidência: II; Estudo Prospectivo.

3.
Acta ortop. bras ; 31(5): e264116, 2023. graf
Article in English | LILACS-Express | LILACS | ID: biblio-1519947

ABSTRACT

ABSTRACT Objective: To evaluate the effectiveness of the dorsal fixation technique with a cannulated compression screw (CCS) for transverse scaphoid neck fractures. Methods: A case series study was carried out with patients treated with a CSS between April 2014 and May 2021. The main outcome was the healing of the fracture, verified by radiographic evaluation that used images of the wrist in anteroposterior, lateral, radial deviation, ulnar deviation and oblique views, obtained in the postoperative period. Results: Fifty-two patients aged between 15 and 65 years were analyzed, of which 43 (83%) were male. Of the 52 patients, 19 (36.53%) had a right-hand injury and 33 (63.46%) had a left-hand injury. Results were excellent in 47 patients (90.38%); good in 4 patients (7.69%), with reduced mobility compared to contralateral and poor in 1 patient (1.92%), with failure of consolidation and breakage of the synthesis material. In 51 cases (99%) there was bone consolidation at the end of six months. Conclusion: Osteosynthesis with a cannulated compression screw is a safe, effective and promising method for the treatment of scaphoid neck fractures. Level of Evidence IV, Case Series.


RESUMO Objetivo: Avaliar a eficácia da técnica de fixação dorsal com parafuso canulado de compressão (CCS) para fraturas transversas do colo do escafoide. Métodos: Foi realizado um estudo de série de casos com pacientes tratados com CSS entre abril de 2014 e maio de 2021. O desfecho principal foi a consolidação da fratura, verificada por meio da avaliação radiográfica das imagens do punho em anteroposterior, perfil, desvio radial, desvio ulnar e oblíquo obtidas no pós-operatório. Resultados: Foram analisados 52 pacientes com idade entre 15 e 65 anos, sendo 43 (83%) do sexo masculino. Dos 52 pacientes, 19 (36,53%) tinham lesão na mão direita e 33(63,46%) na mão esquerda. Os resultados foram excelentes em 47 dos pacientes (90,38%); bons em quatro (7,69%), com mobilidade reduzida comparada ao membro contralateral; e ruim em um (1,92%), com falha da consolidação e quebra do material de síntese. Em 51 casos (99%) houve consolidação óssea ao final de seis meses. Conclusão: A osteossíntese com parafuso canulado de compressão é um método seguro, eficaz e promissor para o tratamento das fraturas no colo do escafoide. Nível de Evidência IV, Série de Casos.

4.
Rev. Ciênc. Méd. Biol. (Impr.) ; 21(2): 161-171, out.2022. fig, tab
Article in Portuguese | LILACS | ID: biblio-1399787

ABSTRACT

Introdução: o tratamento cirúrgico de pacientes com fraturas do processo odontoide tem sido controverso. As principais técnicas cirúrgicas para o segmento C1-C2 incluem além da artrodese cervical (aramagem tipo Gallie, parafusos transarticulares e aramagem tipo 88), a fixação direta com parafuso no processo odontoide. Objetivo: comparar a estabilidade mecânica destes quatro tipos de osteossínteses do segmento atlantoaxial (C1-C2). Metodologia: vinte segmentos atlantoaxiais de cadáveres humanos adultos foram preparados com fraturas do tipo 2 de Anderson e D'Alonso e divididos em quatro grupos: aramagem tipo Gallie (aG); parafusos transarticulares (pT); parafuso no processo odontoide (pD); aramagem tipo 88 (a88). Os corpos de prova foram submetidos a esforços de flexocompressão em máquina universal de ensaios mecânicos para análise de resistência, elasticidade e deformações. Resultados:na fase de acomodação, os parafusos no processo odontoide apresentaram pouquíssima mobilidade com cargas baixas. Na fase de elasticidade, não houve diferença significativa entre as construções testadas. Com relação à resistência máxima suportada pelas construções, houve uma diferença estatisticamente significativa a favor da aramagem tipo Gallie. Conclusão: nossos testes mostraram que em relação à acomodação houve diferença significativa entre a aramagem tipo Gallie e o parafuso no processo odontoide; e quanto à resistência máxima, entre a aramagem tipo Gallie e o parafuso transarticular.


Introduction: the surgical treatment of patients with fractures of the odontoid process has been controversial. The main surgical techniques for C1-C2 are: Gallie wiring, transarticular screw, direct odontoid process screw and 88 posterior laminar wiring. Objective: to compare the mechanical stability of these four types of atlantoaxial segment osteosynthesis (C1/C2). Methodology: twenty atlantoaxial segments of adult human cadavers were prepared with Anderson and D'Alonso type II fractures and divided into four groups: Gallie wiring; transarticular screw; odontoid process screw; 88 wiring. After being fixed with each osteosynthesis technique, they were submitted to flexocompression efforts in a universal mechanical testing machine for analysis of strength, elasticity and deformations. Results: in the accommodation phase, the odontoid process screws showed very little mobility with low loads. In the elasticity phase, there was no significant difference between the constructions tested. With regard to the maximum resistance supported by the constructions, there was a statistically significant difference in favor of Gallie wiring. Conclusion: Our tests showed a significant difference between Gallie wiring and odontoid process screw in accommodation; and between the Gallie wiring and the transarticular screw in maximum resistance test


Subject(s)
Humans , Male , Female , Adult , Spinal Fusion , Fractures, Bone , Fracture Fixation, Internal , Odontoid Process , Cadaver
5.
Rev. bras. ortop ; 57(1): 150-158, Jan.-Feb. 2022. tab, graf
Article in English | LILACS | ID: biblio-1365739

ABSTRACT

Abstract Objective To compare the techniques for the osteosynthesis of intertrochanteric fractures with dynamic hip screws (DHSs) through the Hardinge and minimally-invasive access routes of the hip, evaluating the operative time, the degree of pain in the immediate postoperative period, the hematimetric loss, and the functional aspects of active mobility. Methods A randomized, double-blinded clinical trial in which 66 patients with intertrochanteric fractures were submitted to osteosynthesis by DHS. The patients were divided into a test group, submitted to the minimally-invasive access, and a control group, in whom the surgery was performed through the Hardinge route. Results Patients submitted to the minimally-invasive treatment presented a lower degree of postoperative pain compared to the group treated by the Hardinge lateral route (p< 0.001), as well as lower hematimetric loss (p< 0.001), shorter operative time (p< 0.001), and improvement in immediate postoperative active mobility tests (p <0.05). Conclusion The study demonstrated the clinical superiority of the minimally-invasive access route parameters analyzed in relation to the Hardinge access for the fixation of intertrochanteric fractures when DHS is the choice osteosynthesis method. Level of evidence I.


Resumo Objetivo Comparar as técnicas de osteossíntese de fraturas intertrocantéricas com o parafuso dinâmico de quadril (dynamic hip screw, DHS, em inglês) pelas vias de acesso de Hardinge e minimamente invasiva do quadril, avaliando o tempo cirúrgico, o grau de dor no pós-operatório imediato, a perda hematimétrica, e os aspectos funcionais de mobilidade ativa. Métodos Estudo clínico randomizado e duplo-cego, em que 66 pacientes com fratura intertrocantérica foram submetidos a osteossíntese com DHS. Os pacientes foram divididos em um grupo teste, submetidos ao acesso minimamente invasivo, e um controle, em que a cirurgia foi realizada pela via de Hardinge. Resultados Os pacientes submetidos ao tratamento pela via minimamente invasiva apresentaram um grau de dor pós-operatória inferior em comparação ao grupo tratado pela via lateral de Hardinge (p< 0,001), assim como menor perda hematimétrica (p< 0,001), menor tempo operatório (p< 0,001), e melhora nos testes de mobilidade ativa pós-operatória imediata (p< 0,05). Conclusão O estudo demonstrou a superioridade clínica nos parâmetros analisados da via de acesso minimamente invasiva em relação ao acesso de Hardinge para a fixação de fraturas intertrocantéricas, quando o DHS for a opção de osteossíntese escolhida. Nível de evidência I.


Subject(s)
Humans , Male , Female , Aged , Aged, 80 and over , Pain, Postoperative , Postoperative Period , Control Groups , Clinical Trial , Minimally Invasive Surgical Procedures , Fracture Fixation, Internal , Hip Fractures
6.
Rev. Odontol. Araçatuba (Impr.) ; 42(2): 42-46, maio-ago. 2021. ilus
Article in Portuguese | LILACS, BBO | ID: biblio-1283885

ABSTRACT

Introdução: Por sua posição na face, a mandíbula é frequentemente atingida pelos traumas, surgindo em algumas estatísticas como o osso fraturado com maior incidência em face. Em fraturas de mandíbulas atróficas o tratamento conservador, com fixação intermaxilar não costuma ser uma opção viável pela falta de dentes e pequena área de contato ósseo existente. Dessa forma, a redução aberta e fixação interna estável tem sido o tratamento de escolha sempre que a condição do paciente permitir. Objetivo: relatar um caso de osteossíntese de fratura de mandíbula atrófica por acesso extraoral. Relato de caso: Paciente 64 anos, faioderma, sexo feminino, procurou o serviço de Cirurgia e Traumatologia Bucomaxilofacial da Universidade Federal da Bahia apresentando traumatismo facial por queda da própria altura, referindo severas queixas álgicas espontâneas em região mandibular. Ao exame físico notou-se edentulismo total em ambas as arcadas, edema, hematoma e degrau ósseo á palpação em região de corpo de mandíbula a direita, alémde mobilidade atípica a manipulação da mandíbula. Ao exame de imagem notou-se sinais de fratura em corpo mandibular direito e côndilo esquerdo. O tratamento instituído foiconservador para a fratura de côndilo e cirúrgico para a fratura de corpo, o acesso foi extraoral ea fixação rígida foi realizada com placa e parafusos dos dispositivos Load-Bearing. Considerações finais: A paciente não apresentou quaisquer déficits funcionais pós-procedimento cirúrgico, sendo o tratamento abertocom fixação interna estável bastante promissor por restabelecer a união de focos fraturados e deslocados, proporcionando estabilidade da fratura e conforto imediato para a paciente(AU)


Introduction: Due to its position on the face, the jaw is frequently affected by trauma, appearing in some statistics as the fractured bone with a higher incidence in the face. In fractures of atrophic jaws, conservative treatment, with intermaxillary fixation, is not usually a viable option due to the lack of teeth and small area of existing bone contact. Thus, open reduction and stable internal fixation have been the treatment of choice whenever the patient's condition permits. Objective: to report a case of osteosynthesis of atrophic mandible fracture through extraoral access. Case report: Patient 64-year-old, female, sought the service of Maxillofacial Surgery and Traumatology at the Federal University of Bahia presenting facial trauma due to falling from his own height, referring to severe spontaneous pain complaints in the mandibular region. On physical examination, total edentulism was noted in both arches, edema, hematoma and bone step on palpation in the right jaw body region, in addition to atypical mobility in the jaw manipulation. On imaging examination, signs of fracture were noted in the right mandibular body and left condyle. The treatment instituted was conservative for condyle fracture and surgical for body fracture, access was extraoral and rigid fixation was performed with plate and screws of the Load-Bearing devices. Final considerations: The patient did not presente any functional deficits after the surgical procedure, and the open treatment with stable internal fixation is very promising for restoring the union of fractured and displaced foci, providing fracture stability and immediate comfort for the patient(AU)


Subject(s)
Humans , Female , Middle Aged , Fracture Fixation, Internal , Mandibular Fractures , Atrophy , Jaw, Edentulous , Mandible/surgery
7.
Arq. bras. med. vet. zootec. (Online) ; 73(3): 589-597, May-June 2021. tab, ilus
Article in English | LILACS, VETINDEX | ID: biblio-1278368

ABSTRACT

This study aimed to evaluate the effectiveness of bridge plating of simple tibial fractures in dogs by minimally invasive plate osteosynthesis (MIPO). Medical and radiographic records of twenty-nine dogs with simple tibial fractures that underwent bridge fixation by MIPO were retrospectively evaluated. The clinical outcome was classified considering the presence of lameness at the end of the treatment. The tibial mechanical joint angles were measured and compared with the values described in the literature. Additionally, fragment apposition and implant disposition were evaluated. Based on the modified Radiographic Union Scale for Tibial fractures, the moment of clinical union was determined. Clinically, at the end of treatment, only one patient presented lameness at a trot. While there was no significant difference between the bone alignment in the frontal plane values and the values described in the literature (P>0.05), the caudal proximal tibial angle was significantly higher (P=0.001). The median fragment apposition was considered acceptable. The average bridge plate ratio, plate working length, and plate screw density were 0.8, 0.57, and 0.48, respectively. The median time to clinical union was 30 days. Bridge plating in simple tibial fractures resulted in fast healing and low complication rates.(AU)


Objetivou-se avaliar a efetividade da estabilização em ponte de fraturas tibiais simples em cães utilizando-se a técnica de osteossíntese minimamente invasiva com placa (MIPO). Registros médicos e radiográficos de 29 cães com fraturas simples de tíbia, fixadas em ponte por meio da MIPO, foram retrospectivamente avaliados. O resultado clínico foi classificado com base na deambulação ao final do tratamento. Os ângulos articulares mecânicos da tíbia foram aferidos e comparados aos valores descritos na literatura. Adicionalmente, foram avaliadas a aposição dos fragmentos e a disposição dos implantes. Por meio da escala modificada de união radiográfica para fraturas de tíbia, determinou-se o momento de união clínica. Clinicamente, ao final do tratamento, apenas um animal apresentou claudicação ao trote. Não houve diferença significativa entre o alinhamento ósseo no plano frontal quando comparado com dados da literatura (P>0,05), enquanto, no plano sagital, o ângulo mecânico caudal proximal da tíbia foi significativamente maior (P=0,001). A mediana para aposição dos fragmentos foi considerada aceitável. As médias para relação placa em ponte, comprimento de trabalho da placa e densidade de parafusos da placa foram, respectivamente, 0,8; 0,57 e 0,48. A mediana para união clínica foi de 30 dias. A estabilização em ponte de fraturas tibiais simples resultou em rápida consolidação óssea, com baixas taxas de complicação.(AU)


Subject(s)
Animals , Dogs , Tibial Fractures/veterinary , Fracture Healing , Fracture Fixation, Internal/veterinary , Radiography/veterinary
8.
Arq. bras. med. vet. zootec. (Online) ; 73(3): 647-652, May-June 2021. ilus
Article in English | LILACS, VETINDEX | ID: biblio-1278370

ABSTRACT

The treatment of fractures from the thoracic limb in giant anteaters is extremely challenging. Unfamiliar and peculiar anatomical characteristics, robust musculature and the imminent need for an early return to limb function highlight such challenges. The objective of this report was to describe the successful use of anatomical osteosynthesis with a robust locking compression plate in a humeral fracture of an adult giant anteater. The patient was rescued on the highway after being run over and presented for treatment at the Veterinary Teaching Hospital. Surgical stabilization was performed using a craniomedial approach to the humerus, using a customized broad 3.5mm locking compression plate. The patient presented early limb support at 24 hours postoperatively. Radiographic monitoring was performed at 30, 60 and 90 days postoperatively, and bone healing was observed without any complications. It is concluded that the treatment of humerus fractures in giant anteaters requires robust fixation. The use of a reinforced locking compression plate system proved to be effective and adequate to the mechanical load that an adult individual of this species needs for early use of the thoracic limb and, at the same time, efficient in controlling interfragmentary movement, which allowed fracture consolidation.(AU)


O tratamento das fraturas do membro torácico dos tamanduás-bandeira (Myrmecophaga tridactyla) é extremamente desafiador. Características anatômicas pouco familiares e peculiares, musculatura muito desenvolvida e necessidade iminente de retorno precoce à função do membro destacam tais desafios. Objetivou-se, neste relato, descrever a utilização com sucesso da osteossíntese anatômica com placa bloqueada robusta em fratura umeral de um tamanduá-bandeira. O paciente foi resgatado em rodovia após atropelamento e atendido no Hospital Veterinário Universitário. Após sedação e avaliação física completa, foi realizado exame radiográfico, o qual revelou fratura completa oblíqua curta em diáfise média de úmero esquerdo. A estabilização cirúrgica foi realizada por abordagem craniomedial ao úmero, utilizando-se placa bloqueada (LCP) do sistema 3,5mm customizada. O paciente apresentou apoio precoce do membro com 24 horas de pós-operatório. Realizou-se acompanhamento radiográfico aos 30, 60 e 90 dias, sendo observada união clínica sem quaisquer complicações. Conclui-se que o tratamento das fraturas do úmero em tamanduás-bandeira exige robustez na fixação. A utilização de sistema reforçado de placa bloqueada mostrou-se efetiva e adequada à carga mecânica de que um indivíduo adulto dessa espécie necessita para uso precoce do membro torácico e, ao mesmo tempo, eficiente no controle da movimentação interfragmentária, o qual permitiu consolidação da fratura.(AU)


Subject(s)
Animals , Fracture Healing , Eutheria/surgery , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/veterinary , Humeral Fractures/surgery , Humeral Fractures/veterinary , Bone Plates/veterinary , Animals, Wild/surgery
9.
Braz. J. Vet. Res. Anim. Sci. (Online) ; 58: e182908, 2021. tab, ilus
Article in English | LILACS, VETINDEX | ID: biblio-1363086

ABSTRACT

Many complicated bone fractures can be healed by different techniques including linear external fixation. New generation linear external fixators enhanced the scope of application for bone fractures by mechanical progress. Difficulties include implementing enough pins through fixation clamps to the comminuted fragments or clamp addition and fixing it properly to the rod with the correct pin insertion angle. Effective configurations may not always result. This study sought to reveal the clinical efficiency of modified clamps of a versatile external fixator (VEF) to fix different types of fractures and orthopedic problems according to the radiographic and clinical results. We used this fixator on 17 cats and 17 dogs of different ages and sizes, having different types of antebrachium, humerus, tibia, ulna fractures, and bone-muscle deformities. Clamps had different features to connect fixator pins. Many fixator configurations were created according to the fracture type and body weight of the animals. The most used ones were unilateral and bilateral configurations. The callus formation and visual gait analysis were observed after the operations, until the removal of the fixator. After fixator removal, the visual gait status of the limbs was excellent in 67% of the cases, good in 15%, fair in 12%, and poor in 6%. We found that rods and fixator pins were connected easily by semi-locked clamps. Also, the double pin holding clamps saved space on the fixation rod by the application of two pins through one clamp. We think that clamps of versatile external fixators can easily be constructed to limb fractures and save time during surgery.(AU)


Diversas fraturas ósseas complicadas podem ser tratadas por diferentes técnicas, incluindo fixadores externos lineares. Os fixadores externos lineares de nova geração aumentaram o escopo de aplicação para fraturas ósseas devido ao progresso mecânico. A dificuldade é implementar um número suficiente de pinos através de clamps de fixação aos fragmentos osseos ou adição de clamps com fixação adequadamente à haste com o ângulo correto de inserção do pino. As configurações eficazes nem sempre podem ser realizadas. Este estudo pretendia revelar a eficácia clínica das clamps modificadas de um fixador externo versátil para corrigir diferentes tipos de fraturas e problemas ortopédicos de acordo com os resultados radiográficos e clínicos. O fixador foi utilizado em 17 gatos e 17 cães de diferentes idades e tamanhos, com diferentes tipos de antebraço, úmero, tíbia, fratura de ulna e deformidades ósseo-musculares. Os clamps tinham recursos diferentes para conectar os pinos do fixador. Muitas configurações de fixadores foram criadas de acordo com o tipo de fratura e peso corporal dos animais. As mais utilizadas foram as configurações unilateral e bilateral. A formação do calo e a análise visual da marcha foram observadas após as cirurgias, até a retirada do fixador. Após a retirada do fixador, a utilização dos membros foi excelente em 67% dos casos, bom em 15% dos casos, regular em 12% dos casos, ruim em 6% dos casos. Concluímos que as hastes e os pinos do fixador foram facilmente conectados por clamps semi-travados. Além disso, os clamps de fixação de pino duplo economizaram espaço na haste de fixação com a aplicação de dois pinos em clamp. Acreditamos que os clamps de fixadores externos versáteis podem ser facilmente construídas para fraturas de membros, economizando tempo na cirurgia.(AU)


Subject(s)
Animals , Cats , Dogs , External Fixators/veterinary , Fractures, Bone/therapy , Fractures, Bone/veterinary , Treatment Outcome
10.
Arq. bras. med. vet. zootec. (Online) ; 72(6): 2233-2238, Nov.-Dec. 2020. tab, ilus
Article in Portuguese | LILACS, VETINDEX | ID: biblio-1142293

ABSTRACT

Um filhote de porquinho-da-índia (Cavia porcellus) foi recebido para atendimento após histórico de ataque por cão. Na avaliação física, observou-se edema, dor e crepitação em membro pélvico direito, sugestivo de fratura. Na avaliação radiográfica, confirmou-se fratura Salter-Harris tipo I em epífise distal da tíbia. A resolução cirúrgica escolhida foi a associação de pino transarticular e coaptação externa com tala de Altman. O paciente teve acompanhamento radiográfico semanal e obteve alta médica no 35o dia de pós-cirúrgico, quando se observou consolidação com completo remodelamento ósseo.(AU)


A guinea pig (Cavia porcellus) cub presented edema, pain, and crepitus in the right pelvic limb after being attacked by a dog. Radiographic examination revealed Salter-Harris type 1 fracture on the distal region of the tibia. The surgery technique to correct the fracture involved an association of transarticular pinning and external coaptation with Altman splint. After surgery, radiographs of the patient were performed weekly and on the 35th post-surgery day, the bone was completely remodeled and healed, and the animal was dismissed.(AU)


Subject(s)
Animals , Rodentia/injuries , Bone Nails/veterinary , Fracture Fixation, Intramedullary/veterinary , Tibial Fractures/veterinary , Epiphyses/injuries
11.
Arq. bras. med. vet. zootec. (Online) ; 72(2): 493-498, Mar./Apr. 2020. ilus
Article in Portuguese | LILACS, VETINDEX | ID: biblio-1128385

ABSTRACT

Foi atendida, no Hospital Veterinário da Universidade de Cuiabá, uma coruja suindara (Tyto furcata), resgatada pela Polícia Militar Ambiental, sem histórico, adulta e 400 gramas de peso corporal. A ave apresentava impotência funcional do membro pélvico direito, além de desvio, crepitação e dor na região proximal tibiotársica direita, sem lesão cutânea. Estudo radiográfico revelou fratura diafisária oblíqua curta em tibiotarso direito. A estabilização da fratura foi realizada com placa bloqueada do sistema de 1,5mm, na função de apoio, seis orifícios, com três parafusos monocorticais distais, dois parafusos monocorticais proximais e um parafuso bicortical proximal. Ao 30º dia do pós-operatório, os achados radiográficos de consolidação óssea e o retorno da função do membro permitiram a alta médica. Concluiu-se que o uso de placa bloqueada em função apoio para estabilização de fraturas tibiotársicas simples de coruja suindara oferece resultados satisfatórios.(AU)


An adult suindara owl (Tyto furcata), with no specific history and 400 grams of body weight was treated at the Veterinary Hospital of the University of Cuiabá. The patient presented functional impotence in the right pelvic limb, deviation, crepitation and pain in the proximal region in right tibiotarsal, without cutaneous lesions. Radiographs revealed a short oblique diaphyseal fracture at the right tibiotarsus. Fracture stabilization was performed with a 1.5mm locking plate, buttress, six holes; three distal monocortical screws, two proximal monocortical screws and a proximal bicortical screw. On the 30th postoperative day, radiographic revealed bone healing, and the return of limb function allowed medical discharge. It was concluded that the use of locking plates in buttress function to stabilize simple tibiotarsus fractures in suindara owl offers satisfactory results.(AU)


Subject(s)
Animals , Tibial Fractures/surgery , Bone Plates/veterinary , Strigiformes/surgery , Fractures, Bone/veterinary , Fracture Fixation, Internal/veterinary
12.
Arq. bras. med. vet. zootec. (Online) ; 71(5): 1535-1540, set.-out. 2019. ilus, graf
Article in English | VETINDEX, LILACS | ID: biblio-1038647

ABSTRACT

The objective of this study was to develop a locked tibial-plateau-leveling osteotomy (TPLO) plate and to compare this implant with the conventional bone fixation method using a locked plate to determine bone stabilization against torsion forces. Maximum force, angle at peak torque, and stiffness values were determined. Ten synthetic tibias were used, divided into 2 groups. The results in Group 1 (modified TPLO plate) and Group 2 (locked plate) were assessed using analysis of variance and the means were compared using Tukey's test at 5% probability. There were significant differences in the angle at peak torque and stiffness. The group Modified TPLO plate had higher mean values of stiffness compared with Group locked plate. Group locked plate showed a greater angle at peak torque compared with Group modified TPLO plate. All constructs failed due to tibial fractures distal to the plate. The modified TPLO plate presented higher stiffness indexes than conventional locked plate in torsion. The locked plate presented greater elasticity than modified TPLO plate having greater angle at the peak of torque.(AU)


O objetivo do presente estudo foi desenvolver placa de TPLO bloqueada modificada e avaliar, em ensaio de torção, a estabilização óssea proporcionada pelo implante desenvolvido comparativamente a método de fixação óssea convencional com placa reta bloqueada. As variáveis obtidas foram força máxima, ângulo no pico de torque e rigidez. Foram utilizadas 10 tíbias sintéticas, dividas em dois grupos. Os resultados obtidos do grupo 1 (placa TPLO modificada) e do grupo 2 (placa bloqueada) foram submetidos à análise de variância, e as médias comparadas entre si pelo teste de Tukey a 5% de probabilidade. Houve diferença significativa em relação às variáveis, ângulo no pico de torque e rigidez. Na variável rigidez, a média do grupo placa de TPLO modificada foi maior que a do grupo placa reta bloqueada. Em relação à variável ângulo no pico de torque, o grupo placa reta bloqueada foi superior ao grupo placa de TPLO modificada. Todas as montagens falharam devido à quebra do corpo de prova distal à placa. Conclui-se que a placa de TPLO modificada apresentou maior índice de rigidez que a placa reta convencional sob força de torção. A placa reta bloqueada apresentou maior ângulo no pico de torque, sendo, portando, mais elástica.(AU)


Subject(s)
Animals , Dogs , Prostheses and Implants/veterinary , Orthopedic Procedures/veterinary , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/veterinary , Tibia
13.
Acta ortop. bras ; 27(2): 113-115, Mar.-Apr. 2019. tab
Article in English | LILACS | ID: biblio-989201

ABSTRACT

ABSTRACT Objective: To evaluate the choice of surgical approach among Brazilian orthopedists and whether shoulder surgery specialty training or duration of experience influences the decision-making. Methods: A questionnaire on the preferred approach and complications was administered to orthopedic surgeons with and without shoulder specialization training. The chi-square test or Fisher's exact test was applied. Results: We interviewed 114 orthopedists, 49 (43.0%) traumatologists, 36 (31.5%) specialist surgeons, and 29 (25%) shoulder surgery specialist residents. In cases of fracture without dislocation, specialized training and duration of experience did not influence the approach used (primarily deltopectoral). In cases of fracture/dislocation, 97.2% of the specialists versus 82.1% of the traumatologists opted for the deltopectoral approach (p = 0.034). In cases of fractures/dislocation, 92.5% of surgeons with more than 5 years of experience and 78.7% with less than 5 years of experience opted for the deltopectoral approach (p = 0.032). Conclusion: Specialization in shoulder surgery did not influence surgeons' approaches to manage fractures without dislocation. In cases of fracture/dislocation, shoulder surgery specialization training and duration of experience were associated with selection of the deltopectoral approach. Level of Evidence V, Expert opinion.


RESUMO Objetivo: Avaliar a via de acesso de escolha entre os ortopedistas brasileiros e se a formação de especialista em cirurgia do ombro e/ou tempo de experiência influenciam nessa decisão. Métodos: Realizou-se questionário entre ortopedistas, com e sem especialização em ombro, sobre qual a via de acesso preferida e as complicações observadas. Aplicou-se o teste do qui-quadrado ou o teste exato de Fisher. Resultados: Foram entrevistados 114 ortopedistas, 49 (43,0 %) traumatologistas, 36 (31,5 %) cirurgiões especialistas e 29 (25 %) residentes de especialização em cirurgia do ombro. Nas fraturas sem luxação a formação especializada e o tempo de experiência não influenciaram na escolha (maioria deltopeitoral). Na fratura/luxação, 97,2% dos especialistas optaram pela deltopeitoral, comparado com 82,1% dos traumatologistas (p=0,034). Nas fraturas/luxação, cirurgiões com experiência superior a 5 anos optaram pela deltopeitoral (92,5%) e aqueles com menos de 5 anos optaram pela via deltopeitoral (78,7%) (p=0,032). A diminuição do arco de movimento (ADM) foi a complicação mais relatada. Conclusão: A especialização em cirurgia do ombro não influenciou na escolha nas fraturas sem luxação. Na fratura/luxação, a especialização e o tempo de experiência associaram-se à escolha da via deltopeitoral. A complicação mais frequente foi a diminuição do ADM, principalmente entre os cirurgiões do Ombro. Nível de Evidência V, Opinião de especialistas.

14.
Araçatuba; s.n; 2019. 64 p. ilus, tab, graf.
Thesis in Portuguese | LILACS, BBO | ID: biblio-1051336

ABSTRACT

Este trabalho teve como objetivo avaliar o efeito da biomodulação e bioatividade no reparo ósseo de ratas ovariectomizadas submetidas à simulação de fraturas femurais. Sessenta e quatro ratas Wistar (Rattus novergicus), fêmeas, com 6 meses de idade, em que metade dos animais foram submetidos à ovariectomia bilateral (OVX) e a outra metade à cirurgia fictícia de ovariectomia (SHAM), e um período de 3 meses foi acompanhado para a verificar se a osteoporose estava presente. As ratas foram submetidas à simulação de fratura em ambos os fêmures e a fratura foi fixada com miniplaca e parafusos do sistema 1,5 mm. A metade das amostrastiveram miniplacas com texturização de superfície tratadas por oxidação com plasma eletrolítico (PEO), que ficou em contato com o "gap" reparacional e, a outra metade com miniplacas convencionais, com superfície (CONV). Estes grupos experimentais não foram submetidos à biomodulação (CO). Para o mesmo desenho experimental dos grupos, no ato operatório, após a fixação das fraturas, os demais grupos experimentais foram submetidos à fotobiomodulação por meio da irradiação do laser de baixa intensidade (LASER), durante 5 minutos. Aos 14 e 42 dias de pós-operatório, foi administrada calceína e alizarina, respectivamente, pela via intramuscular, na dose de 20 mg/kg de peso. A eutanásia de todos os animais foi realizada aos 60 dias de pós-operatório. Os grupos experimentais (SHAM/LASER/CONV; SHAM/CO/CONV; SHAM/LASER/PEO; SHAM/CO/PEO; OVX/LASER/CONV; OVX/CO/CONV; OVX/LASER/PEO; OVX/CO/PEO), após a eutanásia, tiveram as regiões de interesse, inicialmente escaneadas em microtomografia computadorizada para avaliação dos parâmetros volumétricos do osso (BV/TV) e qualidade óssea PO(tot) (Tb.Th, Tb.Sp e Tb.N), em seguida as peças continuaram em processamento para inclusão em resina fotopolimerizável. As lâminas foram escaneadas em microscopia confocal a laser para análise da área em pixels2 de precipitação mineral óssea (APMO). Após este processo, as lâminas foram coradas em vermelho de alizarina e azul de Stevenel para histometria de área de osso neoformado (NBF) no "gap" reparacional e análise do padrão reparacional. Os resultados foram inferiores e estatisticamente significantes (p< 0,05) na análise de MicroCT na comparação do grupo OVX/CO/CONV com os demais grupos nos parâmetros (BV.TV, Tb.N e Tb.Th); APMO apresentou menor área para o fluorocromo vermelho de alizarina nos grupos OVX/CO/CONV e OVX/CO/PEO (p<0,05). No grupo OVX, o laser mostrou maior turnover ósseo (p< 0,05) para NBF e pior padrão histológico. Conclusão: A fotobiomodulação e bioatividade otimizaram o reparo ósseo de fraturas em fêmures de ratas ovariectomizadas(AU)


The aim of this study was to evaluate the effect of biomodulation and bioactivity on the bone repair of ovariectomized rats submitted to simulation of femoral fractures. 64 female adults Wistar rats (Rattus novergicus), which half of the animals was submitted to bilateral ovariectomy (OVX) and the other half to the dummy ovariectomy surgery (SHAM), and after 3-month the osteoporosis was induced. The rats were submitted to fracture simulation in both of the femurs and the fracture was fixed with miniplate and screws of the system 1.5 mm. Half of the samples had surface-textured miniplatestreated by with plasma electrolytic oxidation (PEO), which was in contact with the repair gap, and the other half with conventional miniplates with surface (CONV). These experimental groups were not submitted to biomodulation (CO). For the same experimental design of the groups, after fracture fixation, the other experimental groups were submitted to photobiomodulation through low level laser (laser), for 5 minutes. At 14 and 42 postoperative days, calcein and alizarin, respectively, were administered intramuscularly at a dose of 20 mg / kg body weight. The animals were euthanized at 60 postoperative days. The experimental groups (SHAM/LASER/CONV, SHAM/CO/CONV, SHAM/LASER/PEO, SHAM/CO/PEO, OVX/LASER/CONV, OVX/CO/CONV, OVX/LASER/PEO), after euthanasia, had the regions of interest, initially scanned in computerized microtomography to evaluate the bone volume parameters [BV / TV] and bone quality PO (tot) and (Tb.Th, Tb.Sp and Tb.N), then the samples were processed for inclusion in photopolymerizable resin.. The slides were scanned in confocal laser microscopy for analysis of the area in pixels2 of bone mineral precipitation (APMO). After this process, the slides were stained in alizarin red and Stevenel blue for neoformed bone area (NBF) in the reparative gap and analysis of the histology pattern. The results showed lower and statistically significant results (p <0.05) for MicroCT parameters (BV.TV, Tb.N and Tb.Th) in the comparison between OVX / CO / CONV and the other groups; APMO showed lower area for the alizarin red fluorochrome in the OVX / CO / CONV and OVX / CO / PEO groups (p <0.05). In the OVX, the laser showed greater bone turnover (P<0,05); The OVX / CO / CONV showed lower NBF (p <0.05) and worse histological pattern. Conclusion: The photobiomodulation and bioactivity optimized the bone repair of femur fractures in ovariectomized rats(AU)


Subject(s)
Animals , Rats , Osteoporosis , Bone Regeneration , Ovariectomy , Rats, Wistar , Fracture Fixation , Fracture Fixation, Internal
15.
Pesqui. vet. bras ; 38(10): 1909-1912, out. 2018. ilus
Article in English | LILACS, VETINDEX | ID: biblio-976373

ABSTRACT

Technological and tissue engineering have enabled available, biologically inert, and low cost materials to be considered as viable alternatives in the surgical treatment of long bone fractures in birds. The aim of this study was to microscopically analyse osteotomized humerus of birds following the insertion of solid laser-sintered polyamide 12 rods in order to detect foreign body reaction and, thus, verify the bioinert property of the material in the bone fracture environment. Polyamide 12 intramedullary rods were inserted into the osteotomized humerus of 10 birds (white Plymouth Rock) and blocked using 2mm diameter cortical screws of varying lengths. The birds were operated at 60 days of age and monitored post-operatively for three months. Animals were euthanized at 150 days old and samples of the operated humerus collected for immunohistochemistry, light and scanning electron microscopy analysis. Results show bone consolidation without rejection of the implant and absence of inflammatory cells. Vascular Endothelial Growth Factor (VEGF) was expressed in the endothelial cells of the blood vessels at the site of the newly formed bone surrounding the implant, indicative of local angiogenesis. There was no bone growth on the surface of the rod; however, the implant did not interfere with the circumjacent bone repair. Thus, the findings of this study corroborate with the literature in characterizing polyamide as a bioinert material and, under the studied conditions, it can be concluded that polyamide 12 intramedullary rod is biocompatible and provides adequate bone consolidation in humeral fractures with no signs of rejection.(AU)


Com o desenvolvimento tecnológico e crescimento da engenharia de tecidos, o uso de materiais disponíveis, bioinertes e debaixo custo pode ser alternativa viável para o tratamento cirúrgico de fraturas em ossos longos nas aves. O objetivo do estudo foi realizar avaliação microscópica óssea após a implantação de haste maciça de poliamida, implantada em úmeros osteotomizados de galinhas para detectar reação do tipo corpo estranho, verificando a propriedade "bioinerte" do material no ambiente de fratura óssea. Foram utilizados 10 galos (Plymouth rock branca) e implantou-se a haste perfazendo o bloqueio das mesmas com parafusos corticais de 2 mm de diâmetro com comprimentos de acordo com a necessidade. As aves foram operadas aos 60 dias de vida e o acompanhamento pós-operatório ocorreu por três meses. Após a eutanásia, foram realizadas coletas do úmero operado (local de consolidação óssea) paraexame histopatológico, imuno-histoquímico e de microscopia eletrônica de varredura. Os resultados demonstraram consolidação óssea, sem presença de rejeição do material, com ausência de células inflamatórias. A neoformação óssea ao redor do implante expressou VEGF (fator de crescimento endotelial vascular) nas células endoteliais dos vasos sanguíneos caracterizando angiogênese no local. Na região de interface de tecido ósseo com a poliamida não foram observadas micro fraturas. Não houve crescimento ósseo na superfície da haste, porém a mesma não atrapalhou o reparo ósseo circunjacente. Assim, esse estudo corrobora com a literatura caracterizando a poliamida como um material bioinerte, e nas condições estudadas pode-se concluir que o uso da haste intramedular de poliamida 12 proporcionou consolidação óssea nesse modelo biológico nesse tipo de fratura, não havendo indícios de induzir rejeição.(AU)


Subject(s)
Animals , Biocompatible Materials , Biocompatible Materials/adverse effects , Chickens , Fracture Fixation, Internal/veterinary , Fracture Fixation, Intramedullary/veterinary , Host vs Graft Reaction , Nylons
16.
Pesqui. vet. bras ; 38(7): 1376-1381, July 2018. ilus
Article in English | LILACS, VETINDEX | ID: biblio-976446

ABSTRACT

The aim of this study was to describe and analyse the adaptability and functionality of tie-in configuration in tibial osteosynthesis in dogs. Twenty dogs with tibial fracture were included in this study. An orifice was made on the proximal tibial fragment, on the medial side, close to the tibial crest. The drill piece was angled at 45º and projected into the same orifice on the distal sense of the bone. Others orifices made with the aid of a low rotation drill and drill piece with diameter smaller than the chosen implant. After 10 days post-operative, the animals were evaluated. X-ray analysis was performed at the time of clinical examination; immediate post-operative period; and at 30, 60, 90, and 120 days post-surgery. A questionnaire was given to the owners to provide details on the post-operative period. There were no trans-operative complications or suture dehiscence up to the day of suture removal. Partial development of bone callus was observed in 20 dogs within a mean period of 76 days. Three animals showed bone consolidation within 35 days, nine by 60 days, three by 90 days, and 5 by 120 days post-operative. Dynamization was carried out in 9 animals. The surgical access to the tibial medullary canal through the orifice at the proximal medial face, by the tibial tuberosity, enables the insertion of IMP without risks to articular and peri-articular lesions in the knee in dogs.(AU)


O objetivo deste trabalho foi descrever e analisar a funcionalidade da configuração tie-in na ostessíntese de tíbia em cães. Foram usados 21 cães com fratura de tíbia da rotina clinica do hospital veterinário. Somente a primeira cortical (Sis) foi perfurada, em seguida a broca foi inclinada a 45o e projetada no mesmo orifício no sentido distal do osso. foram confeccionados outros orifícios com auxílio de furadeira de baixa rotação e broca cujo diâmetro era menor que o implante escolhido. Os procedimentos radiográficos foram realizados no momento do atendimento clínico, no período pós-operatório imediato e aos 30, 60, 90 e 120 dias pós-cirúrgico. Não houve nenhuma complicação transoperatória, tão pouco deiscência de sutura até o momento da retirada dos pontos de cútis. A formação parcial de calo ósseo foi evidenciada em 20 cães com tempo médio de 76 dias. Três cães obtiveram consolidação óssea em 35 dias, nove aos 60 dias, três aos 90 dias e cinco aos 120 dias de pós-operatório. Dinamizações foram realizadas em nove animais. Após a confirmação radiográfica de consolidação óssea, os implantes dos 20 animais foram totalmente removidos. Concluiu-se que o acesso cirúrgico ao canal medular da tíbia canina por meio de orifício na face medial proximal, junto à tuberosidade da tíbia, permite a inserção do PIM sem risco de lesões articulares e periarticulares no joelho.(AU)


Subject(s)
Animals , Dogs , Postoperative Care/veterinary , Dogs/abnormalities , Fracture Fixation, Internal/veterinary , Fracture Fixation, Internal/statistics & numerical data
17.
Rev. bras. ortop ; 53(2): 136-141, Mar.-Apr. 2018. tab, graf
Article in English | LILACS | ID: biblio-899249

ABSTRACT

ABSTRACT Objective: The objective of this study is to analyze the surgical results of humeral shaft fracture treatment and describe its epidemiology. Methods: Retrospective study that identified all patients treated with surgical fixation of humeral shaft fractures between December of 2014 and June of 2016 in a trauma reference center. All medical records were reviewed in search of epidemiological data referent to the trauma and post-operative results, including radiographic healing of the fracture and related complications. Results: Fifty-one patients were included, mostly male (78.4%), with an average age of 35.02 years. The most common trauma mechanism was a traffic accident (56.9%) followed by same-level falls (17.6%). No statistically significant difference was found between healing time comparing surgical fixation techniques, including open reduction and internal fixation, minimally invasive technique, intramedullary nailing, and external fixation. Conclusion: Although each technique has inherent advantages and disadvantages, all fixation methods proved to be adequate options for the surgical treatment of humeral shaft fractures with high rates of healing and low rates of post-operative complications.


RESUMO Objetivo: Descrever o perfil dos pacientes com fraturas diafisárias do úmero, bem como analisar os resultados das diferentes modalidades cirúrgicas. Método: Estudo retrospectivo baseado na identificação de todos os casos de fraturas diafisárias de úmero submetidas a tratamento cirúrgico entre dezembro de 2014 e junho de 2016 em um serviço de referência em trauma, bem como na análise dos respectivos prontuários, e que buscou dados epidemiológicos referentes ao trauma e resultados pós-operatórios, inclusive tempo de consolidação e complicações relacionadas. Resultados: Foram incluídos 51 pacientes, dos quais a maioria do sexo masculino (78,4%), com média de 35,02 anos. O mecanismo de trauma mais prevalente foram acidentes de trânsito (56,9%), seguidos de quedas de mesmo nível (17,6%). Não foi encontrada diferença significante entre o tempo de consolidação dos diferentes métodos, inclusive redução aberta e fixação interna com placa e parafusos, técnica minimamente invasiva com placa em ponte, haste intramedular e fixação externa. Conclusões: Todos os métodos cirúrgicos avaliados mostraram-se adequadas opções para o tratamento cirúrgico das fraturas da diáfise do úmero, ainda que tenham vantagens e desvantagens inerentes a cada técnica, com altas taxas de consolidação e poucas complicações relatadas.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Aged , Fracture Fixation, Internal , Fracture Fixation, Intramedullary , Humeral Fractures/epidemiology
18.
Pesqui. vet. bras ; 38(2): 335-339, fev. 2018. ilus
Article in Portuguese | LILACS, VETINDEX | ID: biblio-895567

ABSTRACT

Foi atendido um Gavião Caboclo (Buteogallus meridionalis), de vida livre e histórico desconhecido. O paciente apresentava impotência funcional da asa direita e solução de continuidade de aspecto recente envolvendo a região de rádio e ulna direitos caracterizando fratura aberta grau II. Os achados radiológicos foram fratura completa cominutiva de diáfise média de ulna e fratura completa tranversa de diáfise média de rádio. A estabilização da fratura de rádio foi realizada com miniplaca de 1,5mm de 6 orifícios, com 2 parafusos proximais e 2 parafusos distais e, osteossíntese de ulna com placa bloqueada de 2,0mm de 12 orifícios, com 3 parafusos proximais e 2 parafusos distais. Aos 180 dias de pós-operatório, os implantes ortopédicos foram removidos e o paciente recebeu alta. Conclui-se que o emprego de placa bloqueada para tratamento de fraturas abertas em ulna de Gavião Caboclo, pode propiciar adequada consolidação e retorno à função do membro sendo capaz de voar.(AU)


A wild Savanna Hawk (Buteogallus meridionalis) of unknown history, was seen at the veterinary hospital. The patient presented with a dropped right wing and soft tissue damage that appeared to be a recent wound involving the right radius and ulna region, characterizing an open fracture grade II. The radiological findings were a comminuted complete fracture of the ulnar diaphysis and complete transverse fracture of the radial diaphysis. Stabilization of the radius fracture was performed with a 1.5mm miniplate with 6 holes, with 2 proximal screws and 2 distal screws, and ulna osteosynthesis with a 2.0mm locking plate with 12 holes, with 3 proximal screws and 2 distal screws. At 180 postoperative days, the implants were removed and the patient was discharged. The use of locking plate for the treatment of open fractures in ulna of Savanna Hawks may provide adequate healing and return to limb function being able to fly.(AU)


Subject(s)
Animals , Bone Plates/veterinary , Fracture Fixation, Internal/veterinary , Hawks/surgery , Radius Fractures/surgery , Ulna Fractures/surgery , Radius/surgery , Ulna/surgery
19.
Rev. bras. ortop ; 53(1): 88-93, Jan.-Feb. 2018. graf
Article in English | LILACS | ID: biblio-899246

ABSTRACT

ABSTRACT Objective: To determine the ideal working area for a simple transverse fracture line treated with a bridge plate. Methods: A 2-D finite element analysis of a hypothetical femur was performed for the quantitative evaluation of a large-fragment titanium alloy locking plate based on the precept of relative stability in a case of a simple transverse diaphyseal fracture. Two simulations (one case of strain and another case of stress distribution) were analyzed in three unique situations according to the von Mises stress theory. Load distributions were observed when the bone was subjected to a single vertical load of 1000 N. Results: The longer the length of the implant flexion, which coincided with the working area of the plate, the greater the flexion of the implant. The highest concentrations of stress on the plate occurred in the region around the screws closest to the bone gap. The closer the screws to the fracture site, the greater the demands on the plate. Conclusion: When using a large-fragment titanium alloy locking plate to stabilize a simple transverse fracture based on the precept of relative stability (bridge plate), there must be considerable distance between the proximal and distal screws closest to the fracture line. The farther away this fixation is, the lower the stress on the plate and the greater the dissipation of force in the form of deflection.


RESUMO Objetivo: Determinar qual é a área de trabalho ideal em uma fratura de traço simples transverso tratada com placa em ponte. Métodos: Foi feita uma análise bidimensional de elementos finitos em um fêmur hipotético para avaliação quantitativa de uma placa bloqueada para grandes fragmentos feita de liga de titânio, usada com o princípio de estabilidade relativa em uma fratura diafisária de traço simples e transverso. Foram analisadas duas simulações, uma de deformação e outra de distribuição de tensão, de acordo com a teoria de von Mises, em três situações distintas. Foram observadas as distribuições de carga quando o osso foi submetido a uma carga monotônica vertical de 1.000 N. Resultados: Quanto maior o comprimento de flexão do implante, o que coincidiu com a área de trabalho da placa, maior a flexão dele. A maior concentração de tensão na placa foi observada na região dos parafusos mais próximos do defeito ósseo. Quanto mais próximos os parafusos do foco de fratura, maior a demanda sobre a placa. Conclusão: Ao usar uma placa bloqueada para grandes fragmentos feita de liga de titânio para estabilizar uma fratura de traço simples e transverso pelo princípio de estabilidade relativa (placa em ponte), a distância entre os parafusos mais próximos do traço de fratura proximal e distalmente deve ser longa. Quanto mais distante essa fixação, menor a concentração de tensão na placa e maior a dissipação de esforços na forma de deflexão.


Subject(s)
Bone Plates , Bone Regeneration , Finite Element Analysis , Fracture Fixation, Internal
20.
Arq. bras. med. vet. zootec. (Online) ; 69(4)jul.-ago. 2017. ilus
Article in English | LILACS, VETINDEX | ID: biblio-876503

ABSTRACT

The aim of this study was to evaluate the use of polyamide 12 intramedullary rods in osteotomized humerus in cockerels (White Plymouth Rock) and analyze, by radiography and histopathology, bone consolidation and the formation of bone callus. Ten cockerels were subjected to transverse osteotomy of the right humeral diaphysis followed by the insertion of polyamide 12 locked rods, with two nails in each bone fragment. Radiographies obtained at the immediate pre and post-operative period, and every 7 days for 3 months revealed no perioperatory complications. Radiography revealed a radiopaque bone callus between the 4th and 5th week post-surgery. Histopathology detected an amphophylic material (polyamide 12 rod) in the intramedullary region and the proliferation of highly vascularized connective tissue between the rod and the cortical bone. This connective tissue was highly cellular with differentiation into osteoblasts. The collagen fibers varied from loose to dense and a differentiated bone matrix, containing osteocytes in gaps and the development of bone marrow, was also observed; indicating the formation of a bone callus without signs of implant rejection. The polyamide 12 intramedullary rod was effective in the stabilization of the fractures used in this experimental model, with no rejection reaction for at least 90 days.(AU)


O presente estudo teve como objetivo avaliar a implantação de hastes intramedulares de poliamida 12, em úmeros osteotomizados de galos (Plymouth Rock Branca), bem como avaliar a consolidação óssea, por meio da verificação da formação de calo ósseo, analisando exames radiográficos e histopatológicos. Os galos foram submetidos à osteotomia transversa da diáfise do úmero direito, sendo implantadas posteriormente as hastes de poliamida 12 bloqueada com dois parafusos em cada fragmento ósseo. Após o procedimento cirúrgico, foram realizadas radiografias nos momentos pré e pós-operatório imediato e, posteriormente, a cada sete dias, durante três meses, até a realização da eutanásia. Não houve complicações perioperatórias. Ao exame radiográfico, os animais apresentaram formação de calo ósseo radiopaco entre a quarta e quinta semanas de pós-operatório. Ao exame histopatológico, foi possível notar, em todos os animais, presença de material anfofílico (haste de poliamida 12) ocupando a região intramedular óssea, e entre a haste e as corticais ósseas, proliferação de tecido conjuntivo altamente vascularizado. Tal tecido apresentou-se altamente celular com diferenciação em osteoblastos. Notaram-se também fibras colágenas, variando de aspecto frouxo a denso, e observou-se formação de matriz óssea diferenciada com osteócitos em lacunas e formações de medula óssea, denotando formação de calo ósseo sem sinais de rejeição do implante. A haste intramedular de poliamida 12 foi eficaz para estabilização das fraturas utilizando-se esse modelo experimental, sem reação de rejeição pelo período de 90 dias.(AU)


Subject(s)
Animals , Chickens/surgery , Fracture Fixation, Intramedullary/veterinary , Fractures, Bone/surgery , Humerus/injuries , Nylons
SELECTION OF CITATIONS
SEARCH DETAIL